Symptom
Only displaying information in Group Footer 1. Group Header 1 and Detail sections are both marked "Suppress (No Drillldown)" yet when a user clicks on the group footer section they are able to drill down. This is occurring in Crystal Reports and in the HTML viewer.
Resolution
In Crystal Reports itself - insert a text object that overlays the fields in the visible section.
Users are then unable to drill down as they are clicking on the text object rather than the fields.
This works for viewers as well except for the HTML viewer which won't recognize objects over other objects.
Workaround for the customer in the HTML viewer in this case was adding hyperlinks to his fields.
Keywords
drilldown, "drill down", "drill-down", summary, "summary report" , KBA , BI-OD-CR , CrystalReports.com , Problem