Symptom
- ConnectionServer throws a core dump on Unix when the Business Objects Enterprise XI Release 2 services are stopped
- Extract from ConnectionServer log file:
[Mon Mar 23 17:39:34 2009] 19580 3 (APSObjects.cpp:110): trace message: Unknown exception has occurred.
[Mon Mar 23 17:39:34 2009] 19580 3 (APSObjects.cpp:475): trace message: Could not initialize connection to CMS. Removing it from map
[Mon Mar 23 17:39:34 2009] 19580 3 (infosessionmgr.cpp:1717): trace message: CInfoSessionManager:: the aps factory reference is invalid
[Mon Mar 23 17:39:34 2009] 19580 3 trace message: CInfoSessionManager::InvalidateAPS. Invalidating APS
[Mon Mar 23 17:39:34 2009] 19580 3 trace message: the aps factory reference is invalid
[Mon Mar 23 17:39:34 2009] 19580 3 trace message: CInfoSessionManager::InvalidateAPS. Invalidating APS
[Mon Mar 23 17:39:34 2009] 19580 3 trace message: Unable to get cluster members. Reason : Unable to log on: Could not connect to server . Please check that the server name is correct, and that the server is running.
Details : APSObjects.cpp(314)
Could not connect to the Server to get factory :
Extract from stack (last thread):
----------------- lwp# 4 / thread# 4 --------------------
7e1bc6b4 __lwp_park (531ed0, 531e88, 0, 0, 0, 0) + 14
7e1b697c cond_wait_queue (531ed0, 531e88, 0, 0, 0, 0) + 28
7e1b6df4 cond_wait_common (531ed0, 531e88, 0, 0, 0, 0) + 298
7e1b6efc cond_wait (531ed0, 531e88, 7e1e8bc0, 7cbc0400, 531ea8, 0) + 10
7e1b6f38 pthread_cond_wait (531ed0, 531e88, 1, 1, 7f36e9d0, 0) + 8
7f3471b4 __1cKEtc1001204HJTCCondF_wait6Ml_v_ (531ec8, ffffffff, 1edbc, 7f35aa5c, 7f36e9d0, 7f36e9d0) + 158
7f48b0c4 __1cJCORBA_BOANimpl_is_ready6MpnXCORBA_ImplementationDef__v_ (1, 531e68, 7c97b838, 7c97b830, 7c97b828, 7c97b820) + 78
000a2574 __1cLCsContainerDrun6Mb_v_ (7c97b808, 1, 539960, 7c97b7e8, 1, 1) + 33c
7e6fbd20 __1cICXLib301RSUNIXDaemonThreadDrun6M_v_ (5a81d0, 2a8, 4364b0, a2230, 7f36e9d0, 7f36e9d0) + 60
7f34be8c __1cKEtc1001204JJTCThreadU_JTC_startThreadHook6M_b_ (5a81d0, 7f36f730, 7f36e9d0, 0, 7c97bf20, 308) + 170
7f3493ec _JTC_threadAdapter (5a81d0, 2fc, 25614, 7e1bc468, 7f3493b0, 0) + 3c
7e1bc610 _lwp_start (0, 0, 0, 0, 0, 0)