1415084 - What happen if Business Objects servers are stopped or disabled and the time of a WebIntelligence recurrent schedule is reached?

Symptom

  • Recurring schedule jobs behave differently in BusinessObjects Enterprise XIR2, XI 3.1 and XI 3.1 SP2 
  • In BOE XIR2, if BOE servers are down when the time of a recurrent schedule is reached then, once the servers will be up and running again, a job will be launch once and the Instance will succeed
  • In BOE XI 3.1, if BOE servers are down when the time of a recurrent schedule is reached then, once the servers will be up and running again, a job will be launch once and the Instance will failed
  • In BOE XI 3.1 SP2, if BOE servers are down when the time of a recurrent schedule is reached then, once the servers will be up and running again, a job will be launch once and the Instance will succeed
  • Instance failed with error "Cannot initialize Report Engine server. (Error: RWI 00226)" in BOE XI 3.1


Read more...

Environment

  • Business Objects Enterprise XIR2
  • Business Objects Enterprise XI 3.1
  • Business Objects Enterprise XI 3.1 SP2
  • SAP BusinessObjects Business Intelligence Platform (BI) 4.x (including BI 4.0, BI 4.1, BI 4.2, BI 4.3)

Product

SAP BusinessObjects Business Intelligence platform R2 ; SAP BusinessObjects Enterprise XI 3.1

Keywords

recurrence recurrent schedule scheduling job instance instances fail failed success succed business objects enterprise bo boe xi 3.x 3.1 SP2 shut down start restart server servers launch , KBA , BI-BIP-PUB , Publishing and scheduling in InfoView/BI launch pad , BI-BIP , Business intelligence platform , Problem