Symptom
- Getting error: Error #2032 during dashboard Preview in Xcelsius.
- crossdomain.xml file has been placed successfully (as per SAP Knowledge Base 1240845, 1268568, 1359310)
- Flash Global Security Setting has been configured correctly to allow local flash file to refresh data (as per SAP Knowledge Base 1399301)
Environment
- Xcelsius 2008 Enterprise Service Pack 3
- Windows 7 client machine
- Adobe Flash 10.1.53.64
Reproducing the Issue
- Design an Xcelsius model on QaaWS or Live Office connection on relational datasource and set connection to Refresh on Load.
- Click 'Preview' inside Xcelsius.
Cause
Xcelsius 2008 Enterprise SP3 has not been certified to work fine on Windows 7 system. This means some functionality may not work as expected.
Resolution
Install and use Xcelsius Designer as per supported platforms document for SP3 (see Attachment section).
Keywords
Xcelisius Error # 2032 show display xc cx , KBA , BI-RA-XL , Obsolete: BusinessObjects Dashboards and Presentation Design , Problem
Product
SAP BusinessObjects Xcelsius Enterprise 2008
Attachments
Xcelsius2008Enterprise_SupportedPlatforms.pdf |