Symptom
Negative value set in a secondary axis are missing in a combination chart in Xcelsius.
Environment
Xcelsius Enterprise 2008 Service Pack 3
Reproducing the Issue
1.Create a new combination chart.
2.Create two series.
3.Bind series 1 to values “20,40,60”
4.Bind series 2 to values “-20,20,40”
5.Come to “Behavior-Primary Scale”.
6.Choose “Auto (Y) Scale” as “Logarithmic”. (See the series 2, value “-20” will be missed in the chart)
Cause
The issue has been registered as a defect under ADAPT01453931.
Resolution
Apply Fix Pack 3.4 over Xcelsius Service Pack 3.
Keywords
KBA , BI-RA-XL , Obsolete: BusinessObjects Dashboards and Presentation Design , Problem
Product
SAP BusinessObjects Xcelsius Enterprise 2008