SAP Knowledge Base Article - Public

1621561 - Selecting ‘Disable Mouse Input On Load’ for QaaWs connection in Xcelsius permanently disables mouse input after one slice of Pie Chart is clicked.

Symptom

 Selecting ‘Disable Mouse Input On Load’ for QaaWs connection in Xcelsius permanently disables mouse input after one slice of Pie Chart is clicked.

Environment

Xcelsius 2008 Service Pack 3 Fix Pack 3.2

Reproducing the Issue

1. Launch Xcelsius.
2. Take Pie Chart component on canvas and map it with some values.
3. Go to Data Manager, add QaaWS connection, paste QaaWS URL in front of WSDL URL, click on Import and select ‘Disable Mouse Input on load’ under Data Manager.
4. Now go to properties window of Pie Chart component, Navigate to Drill Down tab, check ‘Enable Drill Down’ and map 'Destination' to excel cell.
5. Set drill down cell of Pie Chart component as a Trigger Cell for QaaWS connection and select 'When Value Changes'.
6. Preview the dashboard, click on Pie Chart slice and notice that the mouse input is disabled during data loading.
7. Now click on any slice of Pie Chart before data loading finishes.
8. Notice that the mouse input is disabled permanently.

Resolution

This issue is resolved in Xcelsius 2008 Service Pack 4.

Keywords

KBA , BI-RA-XL , Obsolete: BusinessObjects Dashboards and Presentation Design , Problem

Product

SAP BusinessObjects Xcelsius Enterprise 2008