SAP Knowledge Base Article - Public

1628238 - Using Xcelsius component drill down option does not return to previous selection

Symptom

  • If we drill down through a chart we should be able to return to the position we started or the previous step.

Environment

  • Xcelsius 2008 SP3

Reproducing the Issue

1] Create a dashboard include a pie chart component enabled with the drill down.
2] Navigate to a different lable and back to the old one.
3] The last selected option always remains selected, it is not possible to come back to the previous step.

Cause

This is a By-Design.

Resolution

  • If we drill down trough a chart we are not able to come back to the previous step,
    the last selected option always remains selected as this is the BY-Design of Xcelsius Product.

See Also

Also see ADAPT01515899

Keywords

Drill down, Xcelsius , KBA , BI-RA-XL , Obsolete: BusinessObjects Dashboards and Presentation Design , Bug Filed

Product

SAP BusinessObjects Xcelsius Enterprise 2008