Symptom
Xcelsius Input Text component is locked for the first time when used in a corporate dashboard along with a Web Intelligence (Webi) report.
Environment
- Xcelsius 2008.
- BusinessObjects Enterprise XI 3.1.
- Internet Explorer 7.
Reproducing the Issue
- Create an Xcelsius visualization containing an Input Text component restricted to use only digits.
- Export the Xcelsius dashboard to the BOE platform.
- Create a Corporate Dashboard using Dashboard Builder.
- Place the Xcelsius .swf file into the Corporate Dashboard.
- Save, close and re-open the Corporate Dashboard.
- Click directly inside the Input Text box, values can be entered.
- Edit the Corporate Dashboard, place a Webi report next to the Xcelsius file.
- Save, close and re-open the Corporate Dashboard.
- Click inside the Input Text box, values cannot be entered.
- Click anywhere outside the Xcelsius, then click inside the Input Text box again, now values Can be entered.
- Edit the Corporate Dashboard, remove the Webi report.
- Save, close and re-open the Corporate Dashboard.
- Click inside the Input Text box, values can be entered now.
Cause
The issue has been identified as a defect and is escalated to Product Group under ADAPT01422988.
Resolution
This issue has been targetted to be fixed in Service Pack 3 Fix Pack 2 for Xcelsius 2008.
Keywords
Xcelsius, corporate dashboard. , KBA , BI-RA-XL , Obsolete: BusinessObjects Dashboards and Presentation Design , Bug Filed
Product
SAP BusinessObjects Xcelsius Enterprise 2008