Symptom
A dashboard contains flash variable having blank space word separator e.g."SAP Test". When attempting to save the dashboard to Business Objects Enterprise error message pops up:
"Could not save to Business Objects Enterprise .Invalid property name"
Environment
- BI Platform 4.0
- Dashboards 4.0 SP04 Patch5
Reproducing the Issue
- Create a dashboard.
- Add a flash variable as "SAP Test".
- Save the dashboard to Business Objects Platform.
Cause
The issue is due to space between two words.
Flash variable name should be comprised of only a-z, A-Z, 0-9 or -.
Resolution
Change flash variable name as SAP-Test.
Keywords
Flash Variable, xcelsius, Name , KBA , BI-RA-XL , Obsolete: BusinessObjects Dashboards and Presentation Design , Problem