Symptom
- An error is encountered in the SUM upgrade tool during a Netweaver Support Package update
- The function group for Data Services could not be imported. The upgrade terminates.
- The following error messages occur during SHADOW IMPORT
"/BODS/IDOC_IMPORT (/BODS/RS_DS_BASIS|11)" does not fit into the existing function group "(/BODS/BODS|08)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/IDOC_IMPORT" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/JOB_RUN" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/JOB_RUN (/BODS/RS_DS_BASIS|14)" does not fit into the existing function group "(/BODS/BODS|11)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/JOB_RUN" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/RFC_ABAP_INSTALL_AND_RUN" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/RFC_ABAP_INSTALL_AND_RUN (/BODS/RS_DS_BASIS|17)" does not fit into the existing function group "(/BODS/BODS|15)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/RFC_ABAP_INSTALL_AND_RUN" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/RFC_READ_EXTRACTOR" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/RFC_READ_EXTRACTOR (/BODS/RS_DS_BASIS|18)" does not fit into the existing function group "(/BODS/BODS|34)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/RFC_READ_EXTRACTOR" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/RFC_READ_TABLE" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/RFC_READ_TABLE (/BODS/RS_DS_BASIS|19)" does not fit into the existing function group "(/BODS/BODS|17)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/RFC_READ_TABLE" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/RFC_READ_TABLE2" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/RFC_READ_TABLE2 (/BODS/RS_DS_BASIS|20)" does not fit into the existing function group "(/BODS/BODS|16)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/RFC_READ_TABLE2" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/RFC_READ_TABLE_FILE" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/RFC_READ_TABLE_FILE (/BODS/RS_DS_BASIS|21)" does not fit into the existing function group "(/BODS/BODS|35)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/RFC_READ_TABLE_FILE" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/RFC_STREAM_READ_TABLE" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/RFC_STREAM_READ_TABLE (/BODS/RS_DS_BASIS|22)" does not fit into the existing function group "(/BODS/BODS|36)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/RFC_STREAM_READ_TABLE" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/TABLE_SEARCH" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/TABLE_SEARCH (/BODS/RS_DS_BASIS|25)" does not fit into the existing function group "(/BODS/BODS|20)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/TABLE_SEARCH" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/TEXTS" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/TEXTS (/BODS/RS_DS_BASIS|26)" does not fit into the existing function group "(/BODS/BODS|29)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/TEXTS" not imported in this step.
3 ETW674Xstart import of "LIMUFUNC/BODS/UPLOAD" ...
4 ETW000 1 entry for TADIR~ updated (R3TRFUGR/BODS/RS_DS_BASIS ).
2EETW165 Function "/BODS/UPLOAD (/BODS/RS_DS_BASIS|27)" does not fit into the existing function group "(/BODS/BODS|28)".
2 ETW167 Please transport the whole function group.
3 ETW677 "LIMUFUNC/BODS/UPLOAD" not imported in this step.
Read more...
Environment
- SAP system with Data Services or Information Steward functions installed into /BODS/BODS namespace
- Upgrading Netweaver Support Pack
Product
Keywords
BODS, DS, SAP application, RFC function, /BODS/BODS, fit into, function group , KBA , EIM-DS-SAP , SAP Interfaces , EIM-DS , Data Services , EIM-IS , Information Steward , Bug Filed
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.