SAP Knowledge Base Article - Preview

1916293 - Error WIS 30270 when accessing a linked child report from the SAP BI mobile app

Symptom

  • If the document prompts option is set to ‘Use Document default’ when linking a child report to the parent report with Document Linking in Web Intelligence Web mode the linked child report when accessed from the iPad gives the error “An internal error occurred while calling the ProcessDPCommandsEx (WIS 30270)”
  • The linked child report when accessed from BI Launchpad runs without any issue.
  • If  the option ‘Use Document default’ is not used and instead if the prompt is linked to an object, the child report is accessible from the iPad without any issue.
  • The issue is occurring in the latest version of SAP BI app i.e. 5.0.6. There was no issue in the prior version of SAP BI app i.e. 4.4.28.


Read more...

Product

SAP BusinessObjects Business Intelligence platform 4.0 ; SAP BusinessObjects Mobile 5.0.0 for iPhone and iPad

Keywords

mobi, ipad, iphone, android, tablet, doc, link, opendoc, parameter, gobin, webi, ADAPT01706617, 01706617, ADAPT01706616, 01706616, TE, 5000507818 , KBA , BI-BIP-MOB , Obsolete;use:MOB-APP-BI-BB Blackberry,MOB-APP-BI-SRV server , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.