SAP Knowledge Base Article - Preview

1969240 - SUP Service Fails to Start - MobiLink Fails to Start With Unique Primary Key Error in Log

Symptom

  • Sybase Control Center (SCC) displays the error "Failed to connect to Unwired Server. Ensure the server is running."
  • Sybase Unwired Server service fails to start with Error 1053: The service did not respond to the start or control request in a timely fashion.
  • The SUP server log is not updated.
  • The mlsrv12.exe process isn't running.
  • The MobiLink (mlsrv12.exe) log, mlsrv_err.log, has errors similar to the following:

==========
E. 2014-01-21 19:19:34. <Main> [-10002] Consolidated database server or ODBC error:  ODBC: [Sybase][ODBC Driver][SQL Anywhere]Primary key for table 'ml_scripts_modified' is not unique: Primary key value ('2134-09-08 07:06:05.100000') (ODBC State = 23000, Native error code = -193)
E. 2014-01-21 19:19:34. <Main> [-10076] The MobiLink server was unable to calculate the timestamp precision on the consolidated database using the ml_scripts_modified table.  Timestamp precision related warnings will not be generated
E. 2014-01-21 19:19:34. <Main> [-10382] The MobiLink Server has failed to start
==========


Read more...

Environment

  • Sybase Unwired Platform (SUP) 2.x
  • MobiLink version prior to 12.0.1.4028

Product

Sybase Unwired Platform 2.1

Keywords

KBA , MOB-SUP-SCC , Sybase Control Center Administration , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.