Symptom
- IQ server failure is caused by a double throw when the client application is interrupted during a client file load when message and/or row logging has been specified in the LOAD TABLE statement.
- IQ server crash with a stacktrace including the following functions:
Throw
hos_clientfileio::Write
s_violation::WriteBanner
s_violation::ShutDownLogging
df_Heap::~df_Heap
opt_Driver::~opt_Driver
hos_ObjectStack::Throw
opt_LoadTable::GenerateDFEs
db_LoadTable::Execute
st_command::DoCmdThroughResourceGate
st_iqdml::Load
st_SAIQInterfaceInfo::callFunction
saint_iqthresholddml::Load
dbi_load_table
Note: full stacktrace attached to this document.
Read more...