Symptom
- ASE failed to start after increasing syb_blocking_pool thread count
- Warning messages are logged once every 10 minutes and will repeat until the dataserver process is terminated by a 'kill -9' or 'kill -15'.
Opening Master Database ...
Warning: The internal timer is not progressing. If this message is generated multiple times, report to Sybase Technical Support and restart the server(alarminterval=3).
Warning: The internal timer is not progressing. If this message is generated multiple times, report to Sybase Technical Support and restart the server (alarminterval=23).
- Showserver will have an entry for the active process and 'ipcs -ma' will confirm that shared memory has been allocated.
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 15.7 and 16.0
Product
Keywords
configuration, system, failed, syb_blocking_pool, thread, CR761328, CR#761328, 761328 , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed