Symptom
-
"infected with signal 11" error when selecting from the mon_ProcessStatement MDA table.
Current process (0x50b1150c) infected with signal 11 (SIGSEGV)
Address 0x00000001016edddc (mda_fill_and_send_monProcessStatement+0x218), siginfo (code, address) = (50, 0x2041737365745fd0)
- The following spinlock is reported in the ASE errorlog:
spinlocks held by kpid 1353782540
Spinlock Resource->rprocmgr_spin at address 000000016cbf8f00 owned by 1353782540
- The error is followed by a stacktrace with modules:
mda_fill_and_send_monProcessStatement
mda_std_populate_pid
mda_populate_monProcessStatement
mda_exec
VTABRemoteAccess::startScan
LeScanOp::_LeOpNext
LeSortInputStream
startsort
sort
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 15.7
- SAP Adaptive Server Enterprise (ASE) 16.0
Product
Keywords
CR754648, CR#754648, 754648, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stack, registers , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , BW-SYS-DB-SYB , BW on Adaptive Server Enterprise , Bug Filed
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.