Symptom
- Upgrading pre-ASE CE SP130 to SP130
- Server has user defined logical clusters in the system.
- Error 16860 is reported and failed to upgrade system database
kernel Warning: CIPC Primary network address and listener IP address 10.34.193.104 are identical.
kernel Warning: CIPC Secondary network address and listener IP address 10.34.193.104 are identical.
server Error: 16860, Severity: 1, State: 7
server Unknown logical cluster type: 1889429724 found in sysattributes row for logical cluster: '
Invalid pointer param number 3, pointer value 0x5'.
kernel Fatal error occured during workload manager initialization. Shutting down.
kernel Current process (0x70004) infected with signal 11 (SIGSEGV)
kernel Warning: The internal timer is not progressing. If this message is generated multiple times, report to Sybase Technical Support and restart the server (alarminterval=-940).
kernel Warning: The internal timer is not progressing. If this message is generated multiple times, report to Sybase Technical Support and restart the server (alarminterval=-6940).
kernel Warning: The internal timer is not progressing. If this message is generated multiple times, report to Sybase Technical Support and restart the server (alarminterval=-12940).
...
Read more...
Environment
SAP Adaptive Server Enterprise (ASE) 15.7 Cluster Edition (CE)
Product
Keywords
workload manager, internal timer , KBA , BC-SYB-ASE-CE , ASE Cluster Edition (Standalone) , Bug Filed
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.