Symptom
- Running excessive DDL could cause running out of IQ_SYSTEM_MAIN in Multiplex.
- It also makes coordinator to crash required restarting in Multiplex single-node mode.
[Sample iqmsg when IQ crashed because of running out of IQ_SYSTEM_MAIN]
I. 11/20 18:05:22. 0000000130 Allocation failed. Dbspace IQ_SYSTEM_MAIN is OUT OF SPACE
I. 11/20 18:05:23. 0000000130 Failure on privileged blockmap ; _blockmap @ 600000001f50f728
I. 11/20 18:05:23. 0000000130 Blockmap Member Variables for 600000001f50f728
I. 11/20 18:05:23. 0000000130 From stcxtlib/st_txncb.cxx:5587
I. 11/20 18:05:23. 0000000130 _nextPartitionForHelperFlush = 0
............
I. 11/20 18:05:23. 0000000130 _psuAll = 0
I. 11/20 18:05:23. 0000000130 [s_blockmap_identity]
I. 11/20 18:05:23. 0000000130 _UniqueId: 375241
I. 11/20 18:05:23. 0000000130 _RootBlockId: 0
I. 11/20 18:05:23. 0000000130 _NEntries: 0
I. 11/20 18:05:23. 0000000130 _LastWriterTxnId: 0
I. 11/20 18:05:23. 0000000130 _LastWriterSavePoint: 0
I. 11/20 18:05:23. 0000000130 _FanOutAndFlags2: 0x0
I. 11/20 18:05:23. 0000000130 _Flags: 0x35
I. 11/20 18:05:23. 0000000130 _Version: 1
I. 11/20 18:05:23. 0000000130 _NLinks: 0
I. 11/20 18:05:23. 0000000130 _EntriesPerLink: 0
I. 11/20 18:05:23. 0000000130 _FirstAvailLink: 0
I. 11/20 18:05:23. 0000000130 _MaxLink: 0
I. 11/20 18:05:23. 0000000130 _ModNum: 2
I. 11/20 18:05:23. 0000000130 _RootModNum: 1
I. 11/20 18:05:23. 0000000130 [end s_blockmap_identity]
I. 11/20 18:05:24. 0000000130
I. 11/20 18:05:24. 0000000130
I. 11/20 18:05:24. 0000000130 **************************************************
I. 11/20 18:05:24. 0000000130 *** SAP IQ Abort:
I. 11/20 18:05:24. 0000000130 *** From: slib/s_blockmap.cxx:5166
I. 11/20 18:05:24. 0000000130 *** PID: 23994
I. 11/20 18:05:24. 0000000130 *** Exception Location: 0x9fffffff652b26b0
I. 11/20 18:05:24. 0000000130 *** Error ID: 2096, Exception Type: s_nodbspaceexception
I. 11/20 18:05:24. 0000000130 *** Thread: 112 (TID: 5, Original TID: 5)
I. 11/20 18:05:24. 0000000130 *** Error #: 0, O/S Error #: 0
I. 11/20 18:05:24. 0000000130 **************************************************
I. 11/20 18:05:24. 0000000130
............
I. 11/20 18:06:34. 0000000133 ** While handling one abort, caught signal 11, program abort on thread 109 (TID 8)