Symptom
- Error in tracelog when running batch job where source is IDOC batch: Job <###> is terminated due to error <10149>.
- Error in errorlog:
14.2) 03-05-15 10:07:42 (R) (6972:6060) SYS-170101: |Session test_IDOC_FILE|Data flow df_testIDOCFILE
System Exception <ACCESS_VIOLATION> occurred. Process dump option is off. Process is not dumped.
Call stack:
0x00000000805E5FE1, FlowComm::getRequest()+0049 byte(s),
d:\im_ds_4.2_sp_rel\src\dataservices\dataintegrator\codeline\code\src\flowcomm\flowcomm.cpp, line 0497
0x0000000080DFD60A, RdrJsonMsg::getnext()+0266 byte(s),
d:\im_ds_4.2_sp_rel\src\dataservices\dataintegrator\codeline\code\src\reader\rdrjson.cpp, line 0454
0x0000000080DFC6E6, RdrJsonMsg::execute()+0022 byte(s),
d:\im_ds_4.2_sp_rel\src\dataservices\dataintegrator\codeline\code\src\reader\rdrjson.cpp, line 0405
0x00000000801B93B0, XTran_desc::execute()+0448 byte(s),
d:\im_ds_4.2_sp_rel\src\dataservices\dataintegrator\codeline\code\src\core\xtran.cpp, line 0807
0x00000000810DEB89, Rww_thread::main()+0249 byte(s),
d:\im_ds_4.2_sp_rel\src\dataservices\dataintegrator\codeline\code\src\rww\rww.cpp, line 0451
0x0000000000A7438E, RWThreadFunctionImp::run()+0126 byte(s)
0x0000000000A5C184, RWRunnableImp::exec()+0372 byte(s)
0x0000000000A74643, RWThreadImp::exec()+0051 byte(s)
0x0000000000A75F59, RWThreadImp::_setTimeSliceQuantum()+0169 byte(s)
0x00000000746C37D7, endthreadex()+0071 byte(s)
0x00000000746C3894, endthreadex()+0260 byte(s)
0x000000007790652D, BaseThreadInitThunk()+0013 byte(s)
0x0000000077A3C541, RtlUserThreadStart()+0033 byte(s)
Registers:
RAX=000000000D0CF618 RBX=0000000000000000 RCX=0000000000000000 RDX=000000000D0CF660 RSI=00000000068B1620
RDI=000000000AE26248 RBP=0000000000000000 RSP=000000000D0CF520 RIP=00000000805E5FE1 FLG=0000000000010246
R8=000000000000000A R9=0000000000000007 R10=000000000000070F R11=000000000000001B R12=0000000000000000
R13=000000000000000A R14=0000000000000000 R15=0000000000000000
Exception code: C0000005 ACCESS_VIOLATION
Fault address: 00000001805E5FE1 01:00000000005E4FE1 C:\SAP\SAP BusinessObjects\Data Services\bin\acta.dll
Read more...
Environment
- SAP Data Services 4.2 SP3 and patches
- SAP Data Services 4.2 SP4
Product
SAP Data Services 4.2
Keywords
IDOCS, fail, BODS, ACCESS_VIOLATION, acta.dll, getRequest , KBA , EIM-DS-SAP , SAP Interfaces , Bug Filed