SAP Knowledge Base Article - Preview

2133657 - Signal 11 in ubo_slotscan_getnext - SAP ASE

Symptom

  • Execution of sp_sysmon system procedure
  • Execution of query against the monTask table in master with the KTID and/or ThreadPoolID columns specified
  • ASE error log reports signal 11 error in module ubo_slotscan_getnext:

     kernel  Current process (0x1c3300de) infected with signal 11 (SIGSEGV)
     kernel  Address 0x00000000803c4f3c (ubo_slotscan_getnext+0x1c), siginfo (code, address) = (1, 0x0000000000000000)

  • Stack trace may include modules similar to:

    kisignal
    ubo_slotscan_getnext
    _$o1cfalI0.mda_populate_monTask
    mda_exec
    int VTABRemoteAccess::mdaStartScan
    void VTABRemoteAccess::startScan


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 15.7
  • SAP Adaptive Server Enterprise (ASE) 16.0

Product

SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0

Keywords

VTABRemoteAccess mda_populate_monTask ThreadPoolID monTask , KBA , mda , monitoring table , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results