SAP Knowledge Base Article - Preview

2262379 - 'LOCK TABLE' command is not supported on any Secondary server in Multiplex - SAP IQ

Symptom

  • IQ 16.0 doesn't support 'Lock Table in write mode' in a Secondary server.
  • The following error is reported in IQ 16.0 SP10.x:

(DBA)> lock table "BASE_TAB01" in write mode wait
     Could not execute statement.
     Permission denied: Command not allowed on Multiplex Writer servers.
     (saintlib/saint_iqthresholdddl.cxx 11805)
     SQLCODE=-1004015, ODBC 3 State="HY000" Line 1, column 1

  • However, in IQ 12.7 this feature was successfully used on a Reader node which had Local Store in Multiplex. There was no errors.


Read more...

Environment

  • SAP IQ 16.1
  • SAP IQ 16.0
  • SAP IQ 15.4
  • SAP Sybase IQ 15.2
  • Multiplex

Product

SAP IQ 16.0 ; SAP IQ 16.1 ; SAP Sybase IQ 15.2 ; SAP Sybase IQ 15.4

Keywords

CR793936, CR#793936, 793936 , KBA , BC-SYB-IQ , Sybase IQ , Product Enhancement