Symptom
- When the "auditing" functionality is enabled and a stack overflow is detected.
stack_tracer: stack overflow last chance handler. Task 20644003 has completely exhausted stack at line 2171 in
file /XXXX/XXXX/ase157sp12x/SID/porttree/svr/sql/generic/source/useful/exception.c. Cleanup is no longer possible and task will be killed
- An "Infected with signal 11" error at the function chk_usr_role_audit() is reported in the SAP ASE errorlog.
Current process (0x734b0fab) infected with signal 11 (SIGSEGV)
Address 0x0x000000000126eabc (chk_usr_role_audit+0x2a), siginfo (code, address) = (1, 0x0x0000000000008d98)
- A stack trace with the following functions is reported:
chk_usr_role_audit
chk_and_send_audit
terminate_process
stack_tracer
- Also, a graceful shutdown may hang.
Read more...
Environment
- SAP Adaptive Server Enterprise 15.7
- SAP Adaptive Server Enterprise 16.0
Product
SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0
Keywords
segmentation, fault, segfault, access, violation, stacktrace, crash, hung, stackoverflow, audit, stack_tracer, stack overflow last chance handler, Cleanup is no longer possible and task will be killed, 765517, CR765517 , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Bug Filed