Symptom
- If proxy tables are created on the Accelerator for ASE (A4A) instance that is configured to handle charset ISO_1
- An insert of an extended Ascii character values (Ascii value > 127) will raise error 274:
1> insert p_vchar1 select char(163)
2> go
ODBC error [SQLExecDirect] S1000:1:274:[SAP AG][LIBODBCHDB SO][HDBODBC] General error;274 inserted value too large for column: £
Command has been aborted.
(0 rows affected)
- The above sample attempts to insert the British pound symbol into the proxy table on the A4A.
Read more...
Environment
- SAP HANA ACCELERATOR FOR SAP ASE 1.0 (A4A)
- SAP HANA Platform. Ed. 1.0 SPS10 and SPS 11 (SAP HANA DB)
- SAP Adaptive Server Enterprise (ASE) 16.0
Product
SAP Adaptive Server Enterprise 16.0 ; SAP HANA 1.0 accelerator for SAP ASE
Keywords
Hana, UTF-8, UTF8, charset, 274, varchar, nvarchar, univarchar , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , HAN-ASE , SAP HANA Accelerator for SAP ASE , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.