Symptom
- Received an "infected with signal 11" error in the null() module with a stack trace:
Current process (0x1d900ed) infected with signal 11 (SIGSEGV)
Address 0x0x0000003698e83c1a ((null)+0x3698e83c1a), siginfo (code, address) = (1, 0x(nil))
- Modules seen on the ASE stack trace include:
_memset
actx_set
qa_init
ra__init_qa_hooks
rep_agent_thread
Note: The complete stack trace is available under Attachments.
- In ASE 16.0 SP03, the following error may also be reported when running set_appcontext():
Msg 712, Level 17, State 52:
Server 'ASEname', Line 1:
There is insufficient heap memory to allocate 3 bytes.
Please increase configuration parameter 'heap memory per user' or try again when there is less activity on the system.
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 16.0 SP02 PL03
- SAP Adaptive Server Enterprise (ASE) 16.0 SP03 and SP03 PL01
Product
Keywords
actx_create_attr, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers, CR799010, CR#799010, 799010, CR810282, CR#810282, 810282 , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.