SAP Knowledge Base Article - Preview

2355896 - Error 692 on allocation object when number of devices reaches 256 - SAP ASE

Symptom

  • Corrupted master device
  • Error 692 and write error on disk in ASE errorlog after changing the configuration parameter 'number of devices' from '255' to '256' :
    sddone: write error on virtual disk 0 block 262144: kernel
    sddone: 16384 bytes passed, 0 returned on write for virt disk 0 block 262144

    Error: 692, Severity: 20, State: 1
    Uninitialized logical page '3584' was read while accessing object '99' in database '1'. Please contact Sybase Technical Support.


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 12.5.x

Product

SAP Adaptive Server Enterprise 12.5

Keywords

vdevno, number of devices, 255, 256, configuration parameter, disk init, system table, model, 326312, 338877 , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results