Symptom
After performing a system copy the target system will not start and the following is visible in the indexserver.trc file:
persistence startup failed with ptime exception: fatal error
[29630]{-1}[-1/-1] 2016-10-07 08:39:42.448467 f PersistenceLayer PersistenceController.cpp(00716) : startup failed ERROR [SQL-3] fatal error: A downward catalog migration from 270 to 257 is not supported. at ptime/query/catalog/catalog.cc:969
exception 1: no.71000003 (ptime/query/catalog/catalog.cc:969)
A downward catalog migration from 270 to 257 is not supported.
exception throw location:
1: 0x00007f613326e6c3 in ptime::PtimeError::PtimeError(char const*, int, ptime::PtimeErrorCode::code, char const*, int, int, int)+0x30 at ptime_exception.cc:368 (libhdbrscommon.so)
2: 0x00007f613326e6fc in ptime::PtimeError::create(char const*, int, ptime::PtimeErrorCode::code, char const*, int, int, int)+0x18 at ptime_exception.cc:398 (libhdbrscommon.so)
3: 0x00007f6134038e31 in ptime::Catalog::convertDBImageBeforeRestart()+0x230 at catalog.cc:969 (libhdbrskernel.so)
4: 0x00007f6135574e8f in ptime::Master::recover_memorydb_after_tm_init()+0xeb at ptime_master_start.cc:601 (libhdbrskernel.so)
5: 0x00007f6135575e10 in ptime::Master::poststartup()+0x10 at ptime_master_start.cc:166 (libhdbrskernel.so)
6: 0x00007f6135576a14 in ptime::PTimeFactory::finalize()+0x50 at ptime_factory.cc:504 (libhdbrskernel.so)
Read more...
Environment
SAP Hana Database 1.0
Product
SAP HANA 1.0, platform edition ; SAP HANA, platform edition 2.0
Keywords
KBA , HAN-LM-INS-SAP , Installation of SAP Systems on HANA , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.