SAP Knowledge Base Article - Preview

2390995 - Signal 11 at 'plc__flush' - SAP ASE

Symptom

  • Stack trace on infected with signal 11 at plc__flush():
        
    Current process (0x249066b) infected with signal 11 (SIGSEGV)
    Address 0x0x0000000001882f13 (plc__flush+0x673), siginfo (code, address) = (1, 0x0x0000000000005030)
       
  • The stack trace references the following functions:
         
    plc__flush()
    xls_startscan()
    rec_undo_session()
    abort__all()
    kill_proc()
       
  • ASE was not down and was still available to query. However, there was an orphan process using tempdb in log suspend status, ASE had to be recycled to clear the issue.

     


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 16.0 and higher.

Product

SAP Adaptive Server Enterprise 16.0

Keywords

KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results