Symptom
Under heavy load, IQ DBCC may report inconsistent HG or WD index verify error
sp_iqcheckdb Passed in 16.0 Sp08 and Sp09 .
I. 10/20 04:30:23. 0000004358 ** DBCC Status: Errors Detected ******
I. 10/20 04:30:23. 0000004358 ** Inconsistent Index Count: 2 ******
I. 10/20 04:30:23. 0000004358 ** Block Count Mismatch: -10 ******
I. 10/20 04:30:23. 0000004358 ** Blocks Leaked: 10 ******
I. 10/20 04:30:23. 0000004358 ** 1st Unowned PBN: 330735793 ******
I. 10/20 04:30:23. 0000004358 ** Inconsistent Index: DBA.bench.WD_K500Mc ******
I. 10/20 04:30:23. 0000004358 ** Inconsistent Index: DBA.bench.WD_K500Mv ******
I. 10/20 04:30:23. 0000004358 ** Extra Index RIDs: 2369249438 ******
I. 10/20 04:30:23. 0000004358 ** HG Extra Groups: 2400 ******
I. 10/20 04:30:23. 0000004358 ** HG Extra Keys: 2400 ******
I. 10/20 04:30:23. 0000004358 ** B-Tree Entry Count Errors: 2 ******
Test runs fail in 16.0 Sp10 and Sp11 (mainline) but Passed in 16.0 Sp08 and Sp09 .