Symptom
During Upgrade/update using SUM tool, the phase MAIN_NEWBAS/XPRAS_AIMMRG stops with similar dump,
Directory: /usr/sap/I01/SUM/abap/logName: XPRASSHD.ELG~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~XPRA ERRORS and RETURN CODE in SAPRXXXXXXXX.<SID>~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~1 ETP109 version and release : "380.44.20" "745"1 ETP1982 EPU126XPost-import methods for change/transport request: "SAPK750XPRA90000002"4 EPU111 on the application server: "gersapezci01"2 EPU122XPost-import method "AFTER_IMP_CHDO" started for "CHDO" "L", date and time: "20160802123709"1AETR012XProgram canceled (job "RDDEXECL", number "12370900")1AEPU320 See job log"RDDEXECL""12370900""I01"1 ETP111 exit code : "12">>> PLEASE READ THE REPORT DOCUMENTATION OF THE REPORTS MENTIONED ABOVE <<<=======================================
Following dump in ST22:
========================================
Category Internal kernel error Runtime Errors DDIC_TYPE_INCONSISTENCY Application Component Not assigned Date and Time 10.01.2017 09:34:51 ---------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------- |Short Text | | Inconsistency in the dictionary for structure "EKPO". | ---------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------- |What happened? | | Error in the SAP kernel | | | | The current ABAP program "RM_MEPO_GUI" had to be terminated because the ABAP | | processor detected a system error. | ---------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------- |Error analysis | | There is an internal system error. | | There is an inconsisteny for DDIC structure "EKPO". The corresponding | | Dictionary runtime object (NAMETAB) is incorrect. | | | | The number of components of structure (NAMETAB component "fldcnt") is | | declared as 300. If all the substructures are resolved, and the actual | | total number of components is calculated recursively, a different value | | is returned. | | value is returned.
=====================================
Read more...
Environment
Upgrade/Update using SUM tool.
Product
SAP NetWeaver all versions
Keywords
XPRAS, XPRA, dump, job, cancelled , KBA , BC-UPG-TLS-TLA , Upgrade tools for ABAP , BC-DWB-DIC-AC , ABAP Dictionary Activation and Conversion , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.