SAP Knowledge Base Article - Public

2450371 - Lumira Desktop 'Connect to SAP gateway failed' to local BW with SNC

Symptom

In Lumira Desktop, when connecting to a local SNC enabled BW system, the following error occurs:

Error during connection to BW: Connect to SAP gateway failed Connection

(...)

LOCATION CPIC(TCP/IP) on local host with Unicode ERROR GSS_API(maj)

STOP! – initial call to gss_indicate_mechs() failed TIME Mon Mar 27 18:42:54 2017 RELEASE 721 COMPONENT SNC (Secure Network Communication)

VERSION 6 RC -1 MODULE sncxxdl.c LINE 578 DETAIL SncPDLInit SYSTEM CALL gss_indicate_mechs COUNTER 2

 SNCfail.png

Environment

  • SAP BusinessObjects Lumira Desktop 1.31.X
  • SAP GUI 7.40
  • SNC enabled local BW system
  • SAP Secure Login Client

Reproducing the Issue

  1. In Lumira Desktop, click File > New > Download from Business Warehourse
  2. Select 'Connect to: Local BW System'
  3. Select the SNC enabled BW server, input client ID and language
  4. Click 'Connect'

Cause

The SAP NetWeaver Single Sign-On Secure Login client for NWBC is outdated or otherwise incompatible.

Resolution

The issue has been resolved by updating the SAP Secure Login Client from version 2.0.0.1 to version 2.0.6.1

Keywords

NW SSO, SNC-enabled, BW Extension, Business Warehouse, unable to login, log in , KBA , BI-LUM-DIS , Lumira Desktop/Discovery , Problem

Product

SAP Lumira, desktop edition 1.0