Symptom
- ASE errorlog reports an "infected with signal" 10 or 11 in the module sendtext() or LeSendRow::sendRowToClient() and may be followed by further Signal 11 in the module senderror(). For example:
Current process (0x210011) infected with signal 11 (SIGSEGV)
Address 0x0x0000000000ca2ba6 (sendtext+0x25), siginfo (code, address) = (1, 0x0x00000003e00003f0)
- The stack trace can include modules:
sendtext
LeSendRow::_sendColsToClient
LeSendRow::sendRowToClient
LeEmitSndOp::_LeEoRouteResults
LeEmitSndOp::_LeOpNext
Note: A complete stack trace is available under Attachments.
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 15.7
- SAP Adaptive Server Enterprise (ASE) 16.0 SP02
Product
Keywords
CR80114, CR#801114, 801114, in-row , LOB , inner, outer, join, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, stack, registers, match, 799751, CR799751, CR#799751 , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed