Symptom
- A client connection is terminated when it runs sp_addlogin and alter login in a batch with auditing enable.
- ASE errorlog reports an "infected with signal 11" error in the module oh_findendoffset_inobuf() followed a stack trace:
Current process (0x33001a) infected with signal 11 (SIGSEGV)
Address 0x0x0000000000ee5895 (oh_findendoffset_inobuf+0x13)
- The stack trace includes functions:
oh_findendoffset_inobuf
rvm__get_obfuscated_currstmt
rvm__audit_getcommand_subcommand
form_and_send_audit
rvm__audit_table_view_access
rvm_audit_dispatch
Note: A complete stack trace is available under Attachments.
Read more...
Environment
SAP Adaptive Server Enterprise (ASE) 15.7 and 16.0
Product
Keywords
CR807870, CR#807870, 807870, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed