Symptom
- SAP IQ transactions in a multiplex secondary node start failing, reporting that "All buffer cache pages are in use" messages.
- The SAP IQ iqmsg file contains error messages like:
main Bufman: All buffer cache pages are in use, ask your DBA to increase the size of the buffer cache. slib/s_bufman.cxx
Exception Thrown from slib/s_blockmap.cxx
sp_mpxprocesstlvlog exception, SQLSTATE=QSA31 [main Bufman: All buffer cache pages are in use, ask your DBA to increase the size of the buffer cache
O/S Err#: 0, ErrID: 2097 (s_nobuffersexception); SQLCode: -1009031, SQLState: 'QSA31', Severity: 14
O/S Err#: 0, ErrID: 1025 (db_catalogException); SQLCode: -1009413, SQLState: 'QCB11', Severity: 23
- During busy peak processing periods this may lead to catalog exceptions and an emergency shutdown of the secondary mpx node:
***Emergency Shutdown*
Exception Thrown from dblib/db_iqutility.cxx
O/S Err#: 0, ErrID: 1025 (db_catalogException); SQLCode: -1009413, SQLState: 'QCB11', Severity: 23
Secondary server cannot maintain catalog sync
- This leads to the IQ server shutting down with a Database server shutdown due to HUP signal message in the srv server log
Read more...
Environment
- SAP IQ 16.x
- Multiplex
Product
Keywords
sybase, crash, abort, 'went away', 'writer node', mpx, srvlog, 3708, 5778, 'catalog exception', ev_iqbegintxn, event, tlv , KBA , BC-SYB-IQ , Sybase IQ , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.
SAP Knowledge Base Article - Preview