Symptom
SUM upgrade to Solution Manager 7.2 fails on phase MAIN_SHDRUN/PARDIST_SHD, with the following error in method: COMPUTE_BCD_OVERFLOW.
- ABAP Short Dump Header Data
Short Dump Category: ABAP Programming Error
Runtime Error: COMPUTE_BCD_OVERFLOW
ABAP Program: FUGR SDNT
ABAP Main Program: SAPLSDNT
ABAP Package: SDIC
Software Component: SAP_BASIS
Application Component: BC-DWB-DIC-AC Activation Program, Conversion Program, DB Utility, MC, SPD
- Dump occurs when inserting data into table, TATAF during activation of views:
Frame Program: RDDDISTY
ABAP Program: SAPLSDNT
ABAP Include: LSDNTU12
Line Number: 60
Additional Info: DD_PUT_TATAF
*NOW LOOP OVER PURE STATEMENTS AND COPY THEM TO TTAB.
loop at raw_sql_tab.
ttab-prtext = raw_sql_tab.
add 1 to ttab-posnr.
append ttab.
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 15.7 for Business Suite
- SAP Adaptive Server Enterprise (ASE) 16.0 for Business Suite
- SAP Solution Manager (SOLMAN) 7.2
- SUM 1.0 SP20
Product
Keywords
KBA , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , BC-UPG-TLS-TLA , Upgrade tools for ABAP , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.