2535419 - Signal 11 in ssql_lookup() - SAP ASE 16.0 SP03

Symptom

  • ASE server crashes with signal 11 in the module ssql_lookup() followed by a stack trace a few minutes after restart:

Current process (0x9b004e) infected with signal 11 (SIGSEGV)
Address 0x4000000005ab5f31 (ssql_lookup+0xa01), siginfo (code, address) = (2, 0x000000000000006c)

  • The stack trace includes functions:

ssql_lookup
sqt_get_from_stmtcache 
s__xoltp_dynprepare
internal_sql
curs_convert_to_exec

  Note: A complete stack trace is available under Attachments.

  • The "auto query tuning" is enabled in the ASE server:

auto query tuning = 1


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 16.0 SP03

Product

SAP Adaptive Server Enterprise 16.0

Keywords

spinlock, CR811343,CR#811343, 811343, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers, dynamic, SQL,  statement, cache , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed