SAP Knowledge Base Article - Preview

2544150 - Signal 11 in ind__get_sysindrow() when running DBCC REINDEX on invalid object - SAP ASE 16.0

Symptom

  • When running the "dbcc reindex (<objectname>)" command on an object that is not a table
  • ASE errorlog reports an "infected with signal 11" error in the module ind__get_sysindrow() with a stack trace:

Current process (0x230012) infected with signal 11 (SIGSEGV)
Address 0x0x0000000001b79c50 (ind__get_sysindrow+0x1a0)

  • The stack trace includes functions:

ind__get_sysindrow
ind_nextcopy
table_contain_comp_idx
checktable
reindex

exec_dbcc

  Note: A complete stack trace is available under Attachments.


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 16.0 for Business Suite
  • SAP Adaptive Server Enterprise (ASE) 16.0 

Product

SAP Adaptive Server Enterprise 16.0 ; SAP Solution Manager 7.2

Keywords

SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers, CR811125, CR#811125, 811125 , KBA , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed