2546130 - Signal 11 in startscan() when executing SELECT FOR UPDATE involving MVCC - SAP ASE 16.0

Symptom

  • A client connection is unexpectedly terminated while executing a SELECT FOR UPDATE query involving MVCC.
  • An infected with signal 11 error in the module startscan() followed by a stack trace is reported in the ASE errorlog:

Current process (0x7f0040) infected with signal 11 (SIGSEGV)
Address 0x0x0000000001b0462d (startscan+0xd), siginfo (code, address) = (1, 0x0x0000000000000044)

  • The stack trace includes the following functions:

LeWkTbl::rewindWkTbl
LeCache::LeCacheNext
LeScrContext::updCacheStat
LeInsScrOp::_LeOpOpen

  Note: A complete stack trace is available under Attachments.


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 16.0 SP03 
  • On-Disk Multiversion Concurrency Control (MVCC)

Product

SAP Adaptive Server Enterprise 16.0

Keywords

Sybase, SEGV, segment violation, storage access violation, kisignal, CR808784, CR#808784, 808784, stacktrace , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-SYB-ASE-CE , ASE Cluster Edition (Standalone) , Bug Filed