Symptom
- An "Infected with signal 11" errir is raised in the module pchk__pt_alloc_obj() together with a stack trace:
Current process (0xaf0058) infected with signal 11 (SIGSEGV)
Address 0x0x00000000010a9b05 (pchk__pt_alloc_obj+0x6a5), siginfo (code,520|0 0 00105800 1 762 01:05:16| address) = (1, 0x0x000000070000001f)
- Data compression is enabled for a wide table with 510 and more columns.
- The stack trace includes the following function calls:
pchk__pt_alloc_obj
pchk__pt_alloc_all_obj
pchk_pt_get_objinfo
checkstorage
exec_dbcc
s_excecute
Note: The complete stack trace is available under Attachments.
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 15.7
- SAP Adaptive Server Enterprise (ASE) 16.0
Product
Keywords
ASEServer, CR805808, CR#805808, 805808, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers, dbcc , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed