Symptom

  • Performance starts degrading several days/weeks after the Proxy Server was rebooted.
  • Connection to the Repository takes up to at least 1 minute vs. 5 seconds when using an ODBC Direct connection profile.
  • This also applies to Checking in/out, Comparing models, etc.
  • There is a lot of memory free on the server.
  • The Proxy log file shows that the count of threads (clients) is getting bigger and is not released: the server performance suffers when it reaches a certain level.

warning - status: 58 clients, 60 sockets, 1 db connections, 5.9KB for pipes, 18 own/839 total threads, 369.3MB private bytes, 5.8GB available of 8.5GB physical memory, 6.9GB available of 9.9GB virtual memory
warning - status: 61 clients, 63 sockets, 1 db connections, 6.2KB for pipes, 20 own/771 total threads, 369.8MB private bytes, 5.9GB available of 8.5GB physical memory, 6.9GB available of 9.9GB virtual memory
warning - status: 62 clients, 64 sockets, 1 db connections, 6.3KB for pipes, 21 own/783 total threads, 370MB private bytes, 5.9GB available of 8.5GB physical memory, 6.9GB available of 9.9GB virtual memory
warning - status: 63 clients, 65 sockets, 1 db connections, 6.7KB for pipes, 22 own/785 total threads, 369.8MB private bytes, 5.9GB available of 8.5GB physical memory, 6.9GB available of 9.9GB virtual memory

  • The proxy server is trying to establish a connection to the Repository 20-30 times per second.
    In the log file it looks like the following:

warning - SProxyDbCnct(0): new connection to PD Repository Repository1
warning - SProxyDbCnct(0): new connection to PD Repository Repository2
warning - SProxyDbCnct(0): new connection to PD Repository Repository1
warning - SProxyDbCnct(0): new connection to PD Repository Repository2
... and so on.


Read more...

Environment

SAP PowerDesigner (PD) 16.6

Product

SAP PowerDesigner 16.6

Keywords

DBMS, MSS, Oracle, SQL, perf, response, time, slow, slowness, 811969, CR811969, CR#811969 , KBA , BC-SYB-PD , PowerDesigner , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.