SAP Knowledge Base Article - Public

2697395 - Connector Scheduling - The time of day is invalid.

Symptom

An Admin updates the scheduling time and clicks on save, however gets an information message "The time of day is invalid."

Environment

SuccessFactors Learning Management System (LMS) - All Supported Versions

Reproducing the Issue

Go to a connector and change the scheduled start time - : to a time of hours and minutes 14:00

Cause

1.The Seconds are missing from the time

OR

2.The time and date that is set up on the time and date profile has the hh:mm defined in Capital letters - HH:MM

Resolution

1.Place a seconds counter in with the Hours and Minutes - 14:00:00

2.Go to References- Calanders and Time - Date Format Patterns - Search for the time in use and check that the minutes are in lower case

The reason for this is that the Capital MM are months, you will notice that you can save a time from 1 - 12 but not above while on this setting.

Keywords

Connector,  , KBA , LOD-SF-LMS , Learning Management System , LOD-SF-LMS-CON , Connectors , Problem

Product

SAP SuccessFactors Learning all versions