Symptom

During an upgrade using the Software Update Manager (SUM) an error occurs in the phase MAIN_SHDIMP/XCNV_SHD_LOAD.

 

An error can be found in log file XCNVLOSCHD.ELG as below.

****************************
2EETW109 table "BC325V00" does not exist in nametab.
3WETW109 table "BC325V10" does not exist in nametab.
3WETW000 no entries for BC325V10 will be imported in this step.
2EETW109 table "BC325V10" does not exist in nametab.
3WETW109 table "BC325X00" does not exist in nametab.
3WETW000 no entries for BC325X00 will be imported in this step.
2EETW109 table "BC325X00" does not exist in nametab.
3WETW109 table "BC325X01" does not exist in nametab.
3WETW000 no entries for BC325X01 will be imported in this step.
2EETW109 table "BC325X01" does not exist in nametab.
3WETW109 table "BC325X02" does not exist in nametab.
3WETW000 no entries for BC325X02 will be imported in this step.
2EETW109 table "BC325X02" does not exist in nametab.
3WETW109 table "BC325X03" does not exist in nametab.
3WETW000 no entries for BC325X03 will be imported in this step.
2EETW109 table "BC325X03" does not exist in nametab.
3WETW109 table "BC325X04" does not exist in nametab.
3WETW000 no entries for BC325X04 will be imported in this step.
2EETW109 table "BC325X04" does not exist in nametab.
3WETW109 table "BC325X05" does not exist in nametab.
3WETW000 no entries for BC325X05 will be imported in this step.
2EETW109 table "BC325X05" does not exist in nametab.
3WETW109 table "BC325X06" does not exist in nametab.
3WETW000 no entries for BC325X06 will be imported in this step.
2EETW109 table "BC325X06" does not exist in nametab.
3WETW109 table "BC325X07" does not exist in nametab.
3WETW000 no entries for BC325X07 will be imported in this step.
2EETW109 table "BC325X07" does not exist in nametab.
3WETW109 table "BC325X08" does not exist in nametab.
3WETW000 no entries for BC325X08 will be imported in this step.
2EETW109 table "BC325X08" does not exist in nametab.
3WETW109 table "BC325X09" does not exist in nametab.
3WETW000 no entries for BC325X09 will be imported in this step.
2EETW109 table "BC325X09" does not exist in nametab.
3WETW109 table "BC325X10" does not exist in nametab.
3WETW000 no entries for BC325X10 will be imported in this step.
2EETW109 table "BC325X10" does not exist in nametab.
3WETW109 table "BC325X11" does not exist in nametab.
3WETW000 no entries for BC325X11 will be imported in this step.
2EETW109 table "BC325X11" does not exist in nametab.
3WETW109 table "BC325X12" does not exist in nametab.
3WETW000 no entries for BC325X12 will be imported in this step.
2EETW109 table "BC325X12" does not exist in nametab.
3WETW109 table "BC325X13" does not exist in nametab.
3WETW000 no entries for BC325X13 will be imported in this step.
2EETW109 table "BC325X13" does not exist in nametab.
3WETW109 table "BC325X14" does not exist in nametab.
3WETW000 no entries for BC325X14 will be imported in this step.
2EETW109 table "BC325X14" does not exist in nametab.
3WETW109 table "BC325X15" does not exist in nametab.
3WETW000 no entries for BC325X15 will be imported in this step.
2EETW109 table "BC325X15" does not exist in nametab.
3WETW109 table "BC325X16" does not exist in nametab.
3WETW000 no entries for BC325X16 will be imported in this step.
2EETW109 table "BC325X16" does not exist in nametab.
3WETW109 table "BC325X17" does not exist in nametab.
3WETW000 no entries for BC325X17 will be imported in this step.
2EETW109 table "BC325X17" does not exist in nametab.
3WETW109 table "BC325X18" does not exist in nametab.
3WETW000 no entries for BC325X18 will be imported in this step.
2EETW109 table "BC325X18" does not exist in nametab.
3WETW109 table "BC325X19" does not exist in nametab.
3WETW000 no entries for BC325X19 will be imported in this step.
2EETW109 table "BC325X19" does not exist in nametab.
3WETW109 table "BC325X20" does not exist in nametab.
3WETW000 no entries for BC325X20 will be imported in this step.
2EETW109 table "BC325X20" does not exist in nametab.

****************************

Checking the table ATAB in SE11 you find the field VARDATA is inconsistent.


Read more...

Environment

Product

SAP ERP 6.0

Keywords

BC325X, non-unicode , KBA , BC-UPG-TLS-TLA , Upgrade tools for ABAP , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.