Symptom
- When using "Dump History" feature
- Backups to EMC Networker fail with timestamp errors
- In the Sybase Backup Server log:
Backup Server: 4.124.2.1 Archive API error for device='nsrsyb::ASE.DB.20190128.140139.000::000':
Vendor application name=EMC, Library version=200, API routine=syb_open(),
Message=The time stamp "DB" has non digits in it. Timestamps are composed of digits in the form "YYYYMMDDhhmmsslll"
- In the Networker xbsa.messages log
libnsrsyb error: 2019-01-28 02:01:39 PM: The time stamp "DB" has non digits in it. Timestamps are composed of digits in the form "YYYYMMDDhhmmsslll"
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE)
- EMC Networker Backup utility
Product
Keywords
enable dump history , , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Problem