Symptom
You are receiving the error "No data available or you do not have the necessary Permission" while accessing the homeaddress CSF HRIS element
Environment
SuccessFactors Employee Central
Reproducing the Issue
- Go to Manage Business Configuration
- Go to the HRIS element "homeaddress" for any country
- Error appears "No data available or you do not have the necessary Permission"
Cause
The issue is appearing due to insuffcicient Permissions of the object "ECLocalElementConfig"
Resolution
The Issue can be resolved by two ways. Any of the below can be modified to solve the issue
Solution 1 - Go to Configure Object Definition - Search Object "ECLocalElementConfig" and change its security from YES to NO
Solution 2 - If you do not wish to make the changes suggested in Solution 1, Go to Manage Permission Roles - Open the Desired role which should have this permission - Manage Business Configuration - Search with the label of object "ECLocalElementConfig" and give all permissions
Keywords
ECLocalElementConfig CSF homeaddress No data available or you do not have the necessary Permission HRIS Element , KBA , LOD-SF-EC-PER , Person Data (All Person Data Types) , Problem