SAP Knowledge Base Article - Preview

2812380 - Signal 11 in fglk__send_prom_attn and ASE shuts down - SAP ASE

Symptom

  • The ASE shuts down unexpectedly and the last thing in the errorlog is a signal 11 and stacktrace in function fglk__send_prom_attn.
  • Other routines shown in the stacktrace are: fglk__promotefglk__check_and_promotefg_lock.
  • The failing spid was also holding spinlock Resource->rlockpromotion_spin.
  • Parallelism is configured with  non-default parameters ‘max parallel degree’ and  ‘max query parallel degree‘.


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 16.0 
  • SAP Adaptive Server Enterprise Cluster Edition (ASE CE)

Product

SAP Adaptive Server Enterprise 12.5 ; SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 15.7 Cluster Edition ; SAP Adaptive Server Enterprise 16.0 ; SAP Adaptive Server Enterprise 16.0 Cluster Edition ; Sybase Adaptive Server Enterprise 12.5 ; Sybase Adaptive Server Enterprise 15.0 ; Sybase Adaptive Server Enterprise 15.5 ; Sybase Adaptive Server Enterprise Cluster Edition 15.0 ; Sybase Adaptive Server Enterprise Cluster Edition 15.5 ; Sybase Adaptive Server Enterprise Cluster Edition 15.7

Keywords

CR 826224, 826224, fglk__send_prom_attn, Resource->rlockpromotion_spinP5_ALPHA_THREAD   , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-SYB-ASE-CE , ASE Cluster Edition (Standalone) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.