Symptom
- Connection is unexpectedly terminated.
-
ASE errorlog reports an "infected wiith signal 11" error in the module vu_fixupvar() followed by a stack trace:
Current process (0x133009a) infected with signal 11 (SIGSEGV)
Address 0x0x0000000000f8b6e1 (vu_fixupvar+0xc1), siginfo (code, address) = (1, 0x0x0000000000000040)
- The stack trace include finctions:
vu_fixupvar
vu_fixupview
vu_fixuproot
vu_fixupsubq
vu_mergetrees
vu_analyze_view
vu_call_analyze_view
vu_view_driver
vu_maincmdloop
vu_findviews
vu_res_view
Note: A complete stack trace is available under Attachments.
- The process (spid) was running a query against a view.
Read more...