Symptom
- While recovering tempdb or a user defined tempdb
- ASE crashes with an "infected with signal 11" error in the module crdb__phys:
Current process (0x30002) infected with signal 11 (SIGSEGV)
Address 0x0x0000000002a9de1e (crdb__phys+0x4de), siginfo (code, address) = (1, 0x0x0000000000000078)
- The error comes with a stack trace which contains the following functions:
crdb__phys
crdb_tempdb
recover_tempdb
rec__user_tempdb
Note: A complete stack trace is available under Attachments.
Read more...
Environment
SAP Adaptive Server Enterprise (ASE) 16.0
Product
SAP Adaptive Server Enterprise 16.0
Keywords
Sybase, ASEServer, SAPASE, dataserver, CR820163, CR#820163, 820163, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, stack, registers , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , BC-SYB-ASE-CE , ASE Cluster Edition (Standalone) , Bug Filed