SAP Knowledge Base Article - Preview

2850968 - Signal 11 at OmniQuickPass::expandRangetableName() - SAP ASE

Symptom

  • ASE reports an "infected with signal 11" error in the module OmniQuickPass::expandRangetableName() together with a stack trace:

Current process (0x1050083) infected with signal 11 (SIGSEGV)
Address 0x0x000000000166c757 (OmniQuickPass::expandRangetableName(range*, int, bool, int)+0x853), siginfo (code, address) = (1, 0x0x0000000000000004)

  • The stack trace includes the following modules:

OmniQuickPass::expandRangetableName
OmniQuickPass::handleOJBlock
OmniQuickPass::buildAnsiFrom
OmniQuickPass::generateDelete
OmniQuickPass::generateStatement
LeSQLRep::LeSQLRep
CgGenLava::CGConsDMLOp
...
s_compile
internal_sql

  Note: A complete stack trace is available under Attachments.


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 15.7
  • SAP Adaptive Server Enterprise (ASE) 16.0

Product

SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0

Keywords

CR820144, CR#820144, 820144, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Bug Filed

About this page