SAP Knowledge Base Article - Preview

2921425 - DB6 IBM Db2 LUW . . . SQL1776N The command cannot be issued on an HADR database. Reason code = "1.

Symptom

  • db2diag.log . . . myriads of SQL1776N . . .
       YYYY-MM-DD-24.mm.ss.msmsms+### I11835E761 LEVEL: Warning
       PID : ##### TID : ############# PROC : db2sysc 0
       INSTANCE: db2<sid> NODE : 000 DB : <SID>
       AUTHID : SAPSCP HOSTNAME: <present standby_hostname>
       . . .
       FUNCTION: DB2 UDB, High Availability Disaster Recovery, hdrCheckDb, probe:18200
       MESSAGE : SQL1776N The command cannot be issued on an HADR database. Reason code = "1".
       . . .
       Connections are not allowed on a standby database.

  • R3trans -d . . . trans.log . . .
       SQL1776N The command cannot be issued on an HADR database. Reason code = "1.

  • db2 connect to <SID> . . . command line connection on standby linux server . . .
       SQL1776N The command cannot be issued on an HADR database. Reason code = "1.


Read more...

Environment

IBM Db2 LUW
 DB2 HADR with Tivoli Clustering software . . . Tivoli System Automation for Mutliplatforms (TSAMP) . . . on top

Product

SAP Supply Chain Management 7.0

Keywords

KBA , BC-DB-DB6 , DB2 Universal Database for Unix / NT , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.