SAP Knowledge Base Article - Preview

2922421 - IQ 16 sp11 pl25 crashes while loading data on writer node in mpx with stack "FlushForCommit" -- SAP IQ

Symptom

IQ crash and stacktrace while loading data on writer node in mpx

**************************************************
***   SAP IQ Abort:
***      From:  dblib/db_catalog.cxx:4220
***      Rethrown from:  oslib/hos_throw.cxx:313
***      PID: 255697
***      Exception Location: 0x0x7facdc833380
***      Error ID: 533,  Exception Type: hos_assertexception
***      Thread: 140380410705664  (TID: 3, Original TID: 3)
***      Error #: 3,  O/S Error #: 0
***      Argument:
-- (dblib/db_catalog.cxx 4220)
**************************************************

----- stack frames
db_Catalog::FlushForCommit
st_txnMgr::FlushForCommit
db_FlushForCommit::Execute
st_command::DoCmdThroughResourceGate
st_iqtxn::FlushForCommit
UIQTxn_FlushForCommit
st_SAIQInterfaceInfo::callFunction
st_SAIQInterface::RunIQFunc
st_SAIQInterface::Execute
saint_iqthresholdtxn::FlushForCommit
ri_commit
Connection::commit_work
db__commit


Read more...

Environment

IQ16.0 sp11 pl25 mpx

Product

SAP IQ 16.0

Keywords

821617, CR 821617, CR821617, db_Catalog::FlushForCommit, st_txnMgr::FlushForCommit, db_FlushForCommit::Execute, st_command::DoCmdThroughResourceGate, st_iqtxn::FlushForCommit, UIQTxn_FlushForCommit, st_SAIQInterfaceInfo::callFunction, st_SAIQInterface::RunIQFunc, st_SAIQInterface::Execute, saint_iqthresholdtxn::FlushForCommit, , KBA , BC-SYB-IQ , Sybase IQ , Problem