Symptom
- When accessing a table after adding a new column and a function-based index,
- An "Infected with signal 11" error in the module stat_add_histogram() together with a stack trace is reported in the ASE errorlog:
Current process (0xd10069) infected with signal 11 (SIGSEGV)
Address 0x0x000000000230922c (stat_add_histogram+0x98), siginfo (code, address) = (1, 0x0x0000000100000001)
- The stack trace includes the following functions:
stat_add_histogram
StTcInfo::_StTcCharacterSample
StTcInfo::StTcMrgBnds
StgStatPkg::StgStatPkgSecondaryInit
OptGlobal::_GblSearchEngine
OptGlobal::GblOptimize
Optimize
s_compile_stmt
Note: A complete stack trace is available under Attachments.
- The optdiag output on the table shows a TDS error message at bottom of the file:
Internal error: data length mismatch in ct_fetch().
CTLIB Message: - L4/O2/S6/N36/6/0:
ct_send(): protocol specific layer: internal Client Library error: There is a tds state machine error. An illegal tds token sequence was received.
Optdiag failed. Check for error messages above.
or
Datatype '0' is not supported by Optdiag.
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 15.7 SP140
- SAP Adaptive Server Enterprise (ASE) 16.0 SP03 PL08
Product
Keywords
CR821755, CR#821755, 821755, sprintf_value, statistics, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed