SAP Knowledge Base Article - Preview

2940565 - Signal 11 when ASE tries to acquire SPINLOCK in ind__get_sysindrow() in LWP - SAP ASE

Symptom

  • A process (spid) is terminated.
  • ASE errorlog reports an "infected with signal 11" error in the module text.fdpr.chunk.4() together with a stack trace:

Current process (0x3ef00ed) infected with signal 11 (SIGSEGV)
Address hex#(text.fdpr.chunk.4+0x10)

  • The stack trace includes some or all of these modules:

    text.fdpr.chunk.4
    ind_get__ides
    par_get_ptnids
    LeDMLContext::setupPtnIds
    LeDMLOp::_LeOpAcquire
    LeSequencerOp::_LeOpAcquire
    execproc

  Note: A more complete stack trace is available under Attachments


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 15.7

Product

SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0

Keywords

CR#821728, CR821728, 821728, sybase, stacktrace, LWP, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, registers , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Bug Filed